Bolts Page       Bolts Specs & Testing        Go to Commercial      Survey & Order Form

NORCAT Report on Corrosion Testing of Bolts - COVERING LETTER

th_norcat.gif (2280 bytes)



NORCAT


Northern Centre
for Advanced
Technology Inc.
at Cambrian College


1400 Barrydowne Rd
Sudbury, Ontario
Canada
P3A 3V8


Telephone
(705) 521-8324


Facsimile
(705) 560-9741

March 25, 1999

READ FULL REPORT

Enclosed you will find the report you requested on the relative resistance to corrosion of:

1.   new galvanized friction bolts from Skema Industries.

2.   galvanized friction bolts the same as the first except that they were installed at the NORCAT Underground Centre then pulled out before corrosion testing.

3. plain steel bolts without a galvanized coating


The tests show the clear advantage of galvanized over plain steel and that the damage done by installation has little effect on the corrosion performance of the bolts.

I would suggest that a next step would be longer term corrosion followed by a tensile test which would further substantiate the value of galvanized coatings on longevity.  Your idea of corrosion in simulated or actual sulphide mine water would be interesting as well.

Signed by:
Philip J. Taylor P.Eng.
Department Head
NORCAT Support Services

NEXT PAGE

Send mail to webmaster@phq.com with questions or comments about this web site or travel to Reach Us.

Copyright © 1997 Parts HeadQuarters Inc. All rights reserved. Information in this document is subject to change without notice.